Abstract
This study evaluated bone density in designated implants sites using cone-beam computed tomography (CBCT) and compared the measurements to those of quantitative computed tomography (QCT) and subjective bone density evaluation. Sixty-two designated implant sites in 9 human cadavers jaws were used. Indicator rods, 2 mm in diameter, were placed in all sites. CT images representing 1 mm bucco-lingual slices immediately mesial and distal to the rods were selected for density evaluations. Bone density in Hounsfield units (HU) was assessed in a standardized implant area superimposed on the images, and also subjectively evaluated by 2 independent examiners using the Lekholm & Zarb (1985) classification. Density measurements in HU in most of the areas, except for mesial middle third, of CBCT were comparable to those of QCT with Intraclass Correlation Coefficient values more than 0.8. When CBCT measurements were related statistically to CBCT subjective reading, there was a moderate association interpreted by Spearmans rho value 0.5. However, there was a low agreement of intramachine and inter-machine subjective readings with Kappa statistics value 0.32 and 0.36, respectively. Reproducibility of subjective scoring by Lekholm and Zarb Classification of images from CBCT is not statistically different (P > 0.05) from that of images from QCT. This cone-beam CT machine could be considered as a new modality of diagnostic tool in dental treatment, especially when bone density values are important.
LLU Discipline
Periodontics
Department
Periodontics
School
Graduate School
First Advisor
Max Crigger
Second Advisor
Joseph Caruso
Third Advisor
Eloy Schulz
Degree Name
Master of Science (MS)
Degree Level
M.S.
Year Degree Awarded
2002
Date (Title Page)
12-2002
Language
English
Library of Congress/MESH Subject Headings
Alveolar Bone Loss; Bone Density.
Type
Thesis
Page Count
xi; 38
Digital Format
Digital Publisher
Loma Linda University Libraries
Copyright
Author
Usage Rights
This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights.
Recommended Citation
Aranyarachkul, Prasit, "Assessment of Human Alveolar Bone Density by Using Volumetric CT Machine" (2002). Loma Linda University Electronic Theses, Dissertations & Projects. 858.
https://scholarsrepository.llu.edu/etd/858
Collection
Loma Linda University Electronic Theses and Dissertations
Collection Website
http://scholarsrepository.llu.edu/etd/
Repository
Loma Linda University. Del E. Webb Memorial Library. University Archives